Bauarten

VM2

Versions and Operating Limits

Versions Operating Limits
HN7001 Sliding speed max 0.5 m/s ⇔
Temperature range –200 °C to +240 °C
Service pressure max 300 bar
HN7002 Sliding speed max 0.5 m/s ⇔
Temperature range –200 °C to +240 °C
Service pressure max 100 bar


Numbers of intermediate rings

Pressure range Type HN 7001 Type HN 7002
… up to 8 bar - 2 bis 3
8 to 12 bar 2 4
12 to 30 bar 3 5
30 to 100 bar 4 6
100 to 300 bar 5 -